Category: Research kits

Active filters

Reference: 600670-100

Early screening of a drug candidate’s potential to induce or inhibit CYP1A1/2 is a critical step in the drug development process. Cayman's CYP1A1/2 Induction Reporter Assay Kit is a novel method to assess CYP1A2 induction. Our Reverse Transfection Reporter Assays have overcome many of the disadvantages of other transfection approaches. Cayman's CYP1A1/2 Induction Reporter Assay Kit consists of a 96-well plate coated with a transfection complex containing a Secreted Alkaline Phosphatase (SEAP) reporter construct regulated by the human CYP1A1/2 gene promoter. Cells grown on the CYP1A1/2 Reverse Transfection Strip Plate will introduce the reporter gene into the nucleus. Binding of inducer-activated endogenous transcription factors to the CYP1A1/2 promoter initiates a signal resulting in expression of SEAP which is secreted into the cell culture medium. Aliquots of medium are removed at time intervals beginning at about 24 hours and SEAP activity is measured simply by adding a luminescence-based alkaline phosphatase substrate provided in the kit. The kit is simple to use and can be easily adapted to high-throughput screening for potential CYP1A1 and CYP1A2 inducers.

Reference: 600680-100

Early screening of a drug candidate’s potential to induce or inhibit CYP2B6 is a critical step in the drug development process. Cayman's CYP2B6 Induction Reporter Assay Kit is a novel method to evaluate human Constitutive Androstane Receptor 3 (hCAR3)-mediated CYP2B6 induction for the discovery of hepatic CYP inducers. Our Reverse Transfection Reporter Assays have overcome many of the disadvantages of other transfection approaches. Cayman's CYP2B6 Induction Reporter Assay Kit consists of a 96-well plate coated with a transfection complex containing a Secreted Alkaline Phosphatase (SEAP) reporter regulated by the human CYP2B6 gene promoter. The complex also contains two nuclear receptor expression constructs, human Constitutive Androstane Receptor 3 (hCAR3) and human Hepatocyte Nuclear Factor 4α (HNF4α). Cells grown on the CYP2B6 Reverse Transfection Strip Plate will introduce the reporter gene and express CAR3 and HNF4α. Binding of inducer-activated receptor and transcription factors to the CYP2B6 promoter initiates a signal resulting in expression of SEAP, which is secreted into the cell culture medium. Aliquots of medium are removed at time intervals beginning at about 24 hours and SEAP activity is measured simply by adding a luminescence-based alkaline phosphatase substrate provided in the kit. The kit is simple to use and can be easily adapted to high-throughput screening for potential CAR-mediated CYP2B6 inducers. A known CYP2B6 inducer, CITCO, is included in the kit for use as a positive control.

Reference: 600800-96

The oxygen consumption rate (OCR) of cells is an important indicator of normal cellular function. It is used as a parameter to study mitochondrial function as well as a marker of factors triggering the switch from healthy oxidative phosphorylation to aerobic glycolysis in cancer cells. Oxygen consumption is traditionally measured by a cumbersome oxygen electrode, a specialized piece of equipment that typically yields low sample throughput. A Phosphorescent Oxygen Probe has proven to be useful in measuring oxygen consumption rates in whole cells. Cayman’s cell-based Oxygen Consumption Rate Assay Kit utilizes this newly developed phosphorescent oxygen probe to measure oxygen consumption rate in living cells. Antimycin A, an inhibitor of the mitochondrial electron transport chain, is included to be used as a positive control. Glucose oxidase is also included in the kit to be used as a reference for oxygen depletion. The kit is easy to use and can be easily adapted to high throughput screening for compounds which modulate oxygen consumption rate.