Category: Molecular Biology Reagents

Active filters

  • Categories: Accessory PCR components
  • Categories: Quality Control
  • Categories: Real-Time PCR Master Mix
  • Categories: Sample collection
Reference: ISWAB‐DNA‐1200

DNA collection kit for humans that can capture samples producing high yields of double stranded, long fragmented DNA from buccal cells using traditional swabs.

Reference: PDK0101

highQu PCRbeam™ Fast PCR Detection Kit is a convenient tool for fast detection of gene-specific amplification products obtained by PCR, LAMP or RPA. The detection is based on immunological reaction driven by Biotin and FITC (fluorescein isothiocyanate), thus the amplified DNA shall include Biotin and FITC labels. The PCR amplification has to be performed with one primer labeled with FITC at 5’-end and one primer labeled with Biotin at 5’-end. Alternatively the use of one of the labeled primers can be replaced by gene-specific FITC or Biotin labeled probe. Kit includes PCRbeam™ Membrane Strips that are coated with biotin-ligand on the test band and an anti-rabbit antibody on the control band. The bottom part of the strip which is used for sample application contains an anti-FITC antibody attached to gold particles. PCRbeam™ Detection Buffer is Tris-buffered saline enabling the detection. The PCRbeam™ Fast PCR Detection Kit can be applied for established tests or home-brew assays as a fast and sensitive yes/no detection method. The detection sensitivity is up to 100 fold higher than the one achievable with ethidium bromide stained gels what provides an environment friendly save and economical alternative to the use of mutagen stains. For establishing sensitive PCR-based tests before PCRbeam™ detection we recommend the use of hot-start PCR enzymes or master mixes, like highQu ALLin™ Hot Start Taq Mastermix or ALLin™ Hot Start Taq DNA Polymerase. Principle: The membrane strip is soaked for 10 minutes into the vial with the detection buffer mixed with PCR product. The lateral sample flow driven by gold particles moves the solution up the strip. FITC labeled DNA strand binds with the anti-FITC antibody on the gold particle and Biotin labeled DNA strand is caught by Biotin ligand attached to the test band. As both DNA strands remain hybridized at room temperature, the test band builds an aggregate that develops red-blue color. Excess gold particles that were not caught by FITC move up the strip and the anti-FITC antibody binds to the anti-rabbit antibody to develop the red-blue colored control band. If there is no PCR product in the reaction, then only the control band will be visible. If there is a specific product, the test band will be colored as well.

Reference: QPP0101

highQu qPCR master mixes are based on the small molecular inhibitor technology Hot Start PCR allowing to achieve highest sensitivity and specificity under both standard and fast qPCR cycling conditions. They provide excellent results on both AT and GC rich templates, in multiplexing and guaranty rapid extension with early Ct values with minimum or no optimization. Our master mixes are supplied with PCR Water to guaranty the best performance. To suit the broad instrument range the ORA™ qPCR Probe Master mixes are available in three versions – without ROX, with low or high ROX concentration.

Reference: ISWAB‐DNA‐250

DNA collection kit for humans that can capture samples producing high yields of double stranded, long fragmented DNA from buccal cells using traditional swabs.

Reference: WAT0110

highQu PCR Water is a supplementary high quality reagent for all demanding PCR and qPCR and other molecular biology applications. It saves time being on your bench and guaranties the purity of reactions and inhibition-free performance of PCR reagents. highQu PCR Water is a deionized, membrane filtered water continuously tested in ultrasensitive qPCR and PCR applications, in amplification of long targets and highly specific detection of few copies of templates.

Reference: QPP0105

highQu qPCR master mixes are based on the small molecular inhibitor technology Hot Start PCR allowing to achieve highest sensitivity and specificity under both standard and fast qPCR cycling conditions. They provide excellent results on both AT and GC rich templates, in multiplexing and guaranty rapid extension with early Ct values with minimum or no optimization. Our master mixes are supplied with PCR Water to guaranty the best performance. To suit the broad instrument range the ORA™ qPCR Probe Master mixes are available in three versions – without ROX, with low or high ROX concentration.

Reference: ISWAB‐RNA‐v2

The iSWAB-RNA-v2 device allows for the non-invasive collection, concentration, and stabilization of intact buccal cells and/or any mammalian cells collected with a swab or cytobrush allowing for real time ambient stabilization of total RNA from the point of collection to processing. Maintaining RNA stability and protecting it from degradation is a significant challenge, while current RNA stabilization methods such as PAXgene, Tempus, RNAgard or dry blood spots require invasive blood collection resulting in low compliance. 

Reference: DNL0102

highQu ready to use DNA ladders are mixtures of highly purified plasmid digests and PCR products. The high ladder purity allows for exceptional stability and room temperature storage. Ladders are ready to be directly loaded on agarose gels and are supplied with the loading dye solution for probe DNA. They provide sharp bands for DNA sizing and allow for approximate DNA quantification by comparing the amount of DNA of the band similar in size to your sample band.

Reference: QPP0401

highQu qPCR master mixes are based on the small molecular inhibitor technology Hot Start PCR allowing to achieve highest sensitivity and specificity under both standard and fast qPCR cycling conditions. They provide excellent results on both AT and GC rich templates, in multiplexing and guaranty rapid extension with early Ct values with minimum or no optimization. ORA™ SEE qPCR mixes provide an additional advantage of a simplified tracking of the process, as they are colored with an inert blue dye to make samples much better visible during pipetting and handling. Our master mixes are supplied with PCR Water to guaranty the best performance. To suit the broad instrument range the ORA™ qPCR Probe Master mixes are available in three versions – without ROX, with low or high ROX concentration.