E.Z.N.A.® Endo-Free Plasmid DNA Midi Kit Reference: D6915-00 The E.Z.N.A.® Endo-Free Plasmid DNA Midi Kit provides an efficient method for the large-scale isolation of low-endotoxin plasmid DNA. The system utilizes Lysate Clearance Filter Syringes instead of centrifugation to rapidly clear bacterial lysates post-alkaline lysis. Following lysate clearance, endotoxins are removed, and the protocol follows a simple bind-wash-elute procedure to deliver high-quality plasmid DNA. The yields vary according to plasmid copy number, E. coli strain, and growth conditions. 15-50 mL of bacterial cultures in LB medium typically produces up to 200 µg of high copy number plasmid DNA. Up to 100 mL of culture may be processed when working with low copy number plasmid. The system uses centrifugation or vacuum technology for plasmid purification and eliminates the time-consuming gravity-flow columns that require alcohol precipitation. Purified plasmid DNA is suitable for sensitive downstream applications such as transfection of mammalian cells, cloning, automated fluorescent DNA sequencing (typical reads exceed 800 bp), next-generation sequencing, restriction enzyme digestion, ligation, PCR, in vitro transcription, transformation, etc.
ExtractNow ™ RNA Mini Kit Reference: 603-1010 Purification of total RNA from eukaryotic and microbial materials
E.Z.N.A.® Endo-Free Plasmid DNA Midi Kit Reference: D6915-03 The E.Z.N.A.® Endo-Free Plasmid DNA Midi Kit provides an efficient method for the large-scale isolation of low-endotoxin plasmid DNA. The system utilizes Lysate Clearance Filter Syringes instead of centrifugation to rapidly clear bacterial lysates post-alkaline lysis. Following lysate clearance, endotoxins are removed, and the protocol follows a simple bind-wash-elute procedure to deliver high-quality plasmid DNA. The yields vary according to plasmid copy number, E. coli strain, and growth conditions. 15-50 mL of bacterial cultures in LB medium typically produces up to 200 µg of high copy number plasmid DNA. Up to 100 mL of culture may be processed when working with low copy number plasmid. The system uses centrifugation or vacuum technology for plasmid purification and eliminates the time-consuming gravity-flow columns that require alcohol precipitation. Purified plasmid DNA is suitable for sensitive downstream applications such as transfection of mammalian cells, cloning, automated fluorescent DNA sequencing (typical reads exceed 800 bp), next-generation sequencing, restriction enzyme digestion, ligation, PCR, in vitro transcription, transformation, etc.
ExtractNow™ Virus RNA Swab Reference: 611-2250 Extraction kit based on the reliable spin filter method especially designed for fast isolation of viral RNA from
E.Z.N.A.® Plasmid DNA Maxi Kit Reference: D6922-00 The E.Z.N.A.® Plasmid DNA Maxi Kit utilizes the convenient spin-column format to deliver high-quality plasmid DNA following a simple bind-wash-elute procedure without need for expensive accessories. The yields vary according to plasmid copy number, E. coli strain, and growth conditions. 50-200 mL of bacterial cultures in LB medium typically produces 0.6-1.2 mg of high copy number plasmid DNA. Up to 500 mL of culture may be processed when working with low copy number plasmid. The system uses centrifugation or vacuum technology for plasmid purification and eliminates the time-consuming gravity-flow columns that require alcohol precipitation. Purified plasmid DNA is suitable for automated fluorescent DNA sequencing (typical reads exceed 800 bp), restriction enzyme digestion, ligation, PCR, in vitro transcription, transformation, and other applications.
E.Z.N.A.® Plasmid DNA Maxi Kit Reference: D6922-02 The E.Z.N.A.® Plasmid DNA Maxi Kit utilizes the convenient spin-column format to deliver high-quality plasmid DNA following a simple bind-wash-elute procedure without need for expensive accessories. The yields vary according to plasmid copy number, E. coli strain, and growth conditions. 50-200 mL of bacterial cultures in LB medium typically produces 0.6-1.2 mg of high copy number plasmid DNA. Up to 500 mL of culture may be processed when working with low copy number plasmid. The system uses centrifugation or vacuum technology for plasmid purification and eliminates the time-consuming gravity-flow columns that require alcohol precipitation. Purified plasmid DNA is suitable for automated fluorescent DNA sequencing (typical reads exceed 800 bp), restriction enzyme digestion, ligation, PCR, in vitro transcription, transformation, and other applications.
E.Z.N.A.® Plasmid DNA Maxi Kit Reference: D6922-04 The E.Z.N.A.® Plasmid DNA Maxi Kit utilizes the convenient spin-column format to deliver high-quality plasmid DNA following a simple bind-wash-elute procedure without need for expensive accessories. The yields vary according to plasmid copy number, E. coli strain, and growth conditions. 50-200 mL of bacterial cultures in LB medium typically produces 0.6-1.2 mg of high copy number plasmid DNA. Up to 500 mL of culture may be processed when working with low copy number plasmid. The system uses centrifugation or vacuum technology for plasmid purification and eliminates the time-consuming gravity-flow columns that require alcohol precipitation. Purified plasmid DNA is suitable for automated fluorescent DNA sequencing (typical reads exceed 800 bp), restriction enzyme digestion, ligation, PCR, in vitro transcription, transformation, and other applications.
E.Z.N.A.® FastFilter Plasmid DNA Maxi Kit Reference: D6924-00 The E.Z.N.A.® FastFilter Plasmid DNA Maxi Kit combines the convenience of spin columns with the speed of syringe filters to ease large-scale plasmid preparations. The system utilizes Lysate Clearance Filter Syringes instead of centrifugation to rapidly clear bacterial lysates post-alkaline lysis and follows a simple bind-wash-eluteâ procedure to deliver high-quality plasmid DNA. The yields vary according to plasmid copy number, E. coli strain, and growth conditions. 50-200 mL of bacterial cultures in LB medium typically produces 0.6-1.2 mg of high copy number plasmid DNA. Up to 500 mL of culture may be processed when working with low copy number plasmid. The system uses centrifugation or vacuum technology for plasmid purification and eliminates the time-consuming gravity-flow columns that require alcohol precipitation. Purified plasmid DNA is suitable for automated fluorescent DNA sequencing (typical reads exceed 800 bp), restriction enzyme digestion, ligation, PCR, in vitro transcription, transformation, and other applications.
E.Z.N.A.® FastFilter Plasmid DNA Maxi Kit Reference: D6924-03 The E.Z.N.A.® FastFilter Plasmid DNA Maxi Kit combines the convenience of spin columns with the speed of syringe filters to ease large-scale plasmid preparations. The system utilizes Lysate Clearance Filter Syringes instead of centrifugation to rapidly clear bacterial lysates post-alkaline lysis and follows a simple bind-wash-eluteâ procedure to deliver high-quality plasmid DNA. The yields vary according to plasmid copy number, E. coli strain, and growth conditions. 50-200 mL of bacterial cultures in LB medium typically produces 0.6-1.2 mg of high copy number plasmid DNA. Up to 500 mL of culture may be processed when working with low copy number plasmid. The system uses centrifugation or vacuum technology for plasmid purification and eliminates the time-consuming gravity-flow columns that require alcohol precipitation. Purified plasmid DNA is suitable for automated fluorescent DNA sequencing (typical reads exceed 800 bp), restriction enzyme digestion, ligation, PCR, in vitro transcription, transformation, and other applications.
E.Z.N.A.® Plasmid DNA Mini Kit I Reference: D6942-00 The E.Z.N.A.® Plasmid DNA Mini Kit I is designed to isolate up to 25 µg of high-quality plasmid DNA from 1-5 mL bacterial cultures in less than 30 minutes. Plasmid DNA purification follows the alkaline-lysis method and is simplified with HiBind® Mini Column technology into three quick steps: Bind, Wash, and Elute. Purified plasmid DNA is immediately ready for a wide variety of downstream applications such as routine screening, restriction enzyme digestion, transformation, PCR and DNA sequencing. The E.Z.N.A.® Plasmid DNA Mini Kit is available in two formats Q-spin (D6942) and V-spin (D6943). D6942 (Q-spin) features columns that are capless whereas D6943 (V-spin) includes columns that have a cap attached. The columns are otherwise identical in use and application and can be used in both vacuum or centrifugation protocols.
E.Z.N.A.® Plasmid DNA Mini Kit I Reference: D6942-01 The E.Z.N.A.® Plasmid DNA Mini Kit I is designed to isolate up to 25 µg of high-quality plasmid DNA from 1-5 mL bacterial cultures in less than 30 minutes. Plasmid DNA purification follows the alkaline-lysis method and is simplified with HiBind® Mini Column technology into three quick steps: Bind, Wash, and Elute. Purified plasmid DNA is immediately ready for a wide variety of downstream applications such as routine screening, restriction enzyme digestion, transformation, PCR and DNA sequencing. The E.Z.N.A.® Plasmid DNA Mini Kit is available in two formats Q-spin (D6942) and V-spin (D6943). D6942 (Q-spin) features columns that are capless whereas D6943 (V-spin) includes columns that have a cap attached. The columns are otherwise identical in use and application and can be used in both vacuum or centrifugation protocols.
E.Z.N.A.® Plasmid DNA Mini Kit I Reference: D6942-02 The E.Z.N.A.® Plasmid DNA Mini Kit I is designed to isolate up to 25 µg of high-quality plasmid DNA from 1-5 mL bacterial cultures in less than 30 minutes. Plasmid DNA purification follows the alkaline-lysis method and is simplified with HiBind® Mini Column technology into three quick steps: Bind, Wash, and Elute. Purified plasmid DNA is immediately ready for a wide variety of downstream applications such as routine screening, restriction enzyme digestion, transformation, PCR and DNA sequencing. The E.Z.N.A.® Plasmid DNA Mini Kit is available in two formats Q-spin (D6942) and V-spin (D6943). D6942 (Q-spin) features columns that are capless whereas D6943 (V-spin) includes columns that have a cap attached. The columns are otherwise identical in use and application and can be used in both vacuum or centrifugation protocols.