Category: Antibodies

Active filters

  • Categories: Antibody panels
  • Categories: Control Antibodies
  • Categories: ELISA Antibody Pairs
  • Categories: Kits
Reference: AS06 146

There is a confirmed cross-reaction with TLA1 protein in Chlamydomonas reinhardtii.For samples with a very low PSII content theremight be detection problems independent of the antibody. PSII proteins can vary in level depending upon liquid culture conditions. When the cells are in a stationary phase PSII content can drop to a very low level.

Reference: KHC0007

KHC0007 is a ready-to-use IHC kit for staining of CD206(MRC1). The kit provides all reagents, from antigen retrieval to cover slip mounting, that require little to no diluting or handling prior to use. Simply apply the reagents to your sample slide according to the protocol and you're steps away from obtaining high-quality IHC data.

Reference: AS08 325

References describing immunolocalization (IF) and (IG) studies:Pimpl et al (2000). In Situ Localization and in Vitro Induction of Plant COPI-Coated Vesicles. Plant Cell. 2000 Nov;12(11):2219-36.Ritzenthaler et al. (2002). Reevaluation of the Effects of Brefeldin A on Plant Cells Using Tobacco Bright Yellow 2 Cells Expressing Golgi-Targeted Green Fluorescent Protein and COPI Antisera. Plant Cell. 2002 Jan;14(1):237-61.

Reference: KHC0023

KHC0023 is a ready-to-use IHC kit for staining of CD34. The kit provides all reagents, from antigen retrieval to cover slip mounting, that require little to no diluting or handling prior to use. Simply apply the reagents to your sample slide according to the protocol and you're steps away from obtaining high-quality IHC data.

Reference: AS08 330S

Concentration: after adding 225 µl of milliQ water final concentration of the standard is 0.15 pmol/µlProtein standard buffer composition: Glycerol 10%, Tris Base 141 mM, Tris HCl 106 mM, LDS 2%, EDTA 0.51 mM, SERVA® Blue G250 0.22 mM, Phenol Red 0.175 mM, pH 8.5, 0.1mg/ml PefaBloc protease inhibitor (Roche), 50mM DTT.This standard is ready-to-load and does not require any additions or heating. It needs to be fully thawed and thoroughly mixed prior to using. Avoid vigorous vortexing, as buffers contain detergent. Following mixing, briefly pulse in a microcentrifuge to collect material from cap.This standard is stabilized and ready and does not require heating before loading on the gel. Please note that this product contains 10% glycerol and might appear as liquid but is provided lyophilized. Allow the product several minutes to solubilize after adding water. Mix thoroughly but gently Take extra care to mix thoroughly before each use, as the proteins tend to settle with the more dense layer after freezing.

Reference: KHC0039

KHC0039 is a ready-to-use IHC kit for staining of Vimentin. The kit provides all reagents, from antigen retrieval to cover slip mounting, that require little to no diluting or handling prior to use. Simply apply the reagents to your sample slide according to the protocol and you're steps away from obtaining high-quality IHC data.

Reference: AS08 371S

Concentration: after re-constitution with sterile milliQ water final concentration of the standard is 0.15 pmoles/µlProtein standard buffer composition: Glycerol 10%, Tris Base 141 mM, Tris HCl 106 mM, LDS 2%, EDTA 0.51 mM, SERVA® Blue G250 0.22 mM, Phenol Red 0.175 mM, pH 8.5, 0.1mg/ml PefaBloc protease inhibitor (Roche), 50 mM DTT.This standard is ready-to-load and does not require any additions or heating. It needs to be fully thawed and thoroughly mixed prior to using. Avoid vigorous vortexing, as buffers contain detergent. Following mixing, briefly pulse in a microcentrifuge to collect material from cap.This standard is stabilized and ready and does not require heating before loading on the gel. Please note that this product contains 10% glycerol and might appear as liquid but is provided lyophilized. Allow the product several minutes to solubilize after adding water. Mix thoroughly but gently Take extra care to mix thoroughly before each use, as the proteins tend to settle with the more dense layer after freezing.

Reference: KHC0027

KHC0027 is a ready-to-use IHC kit for staining of CD11B(Integrin Alpha M). The kit provides all reagents, from antigen retrieval to cover slip mounting, that require little to no diluting or handling prior to use. Simply apply the reagents to your sample slide according to the protocol and you're steps away from obtaining high-quality IHC data.

Reference: AS09 018S

Concentration: after adding 225 µl of milliQ water final concentration of the standard is 0.20 pmol/µlProtein standard buffer composition: Glycerol 10%, Tris Base 141 mM, Tris HCl 106 mM, LDS 2%, EDTA 0.51 mM, SERVA® Blue G250 0.22 mM, Phenol Red 0.175 mM, pH 8.5, 0.1 mg/ml PefaBloc protease inhibitor (Roche), 50mM DTT.This standard is ready-to-load and does not require any additions or heating. It needs to be fully thawed and thoroughly mixed prior to using. Avoid vigorous vortexing, as buffers contain detergent. Following mixing, briefly pulse in a microcentrifuge to collect material from cap.This standard is stabilized and ready and does not require heating before loading on the gel. Please note that this product contains 10% glycerol and might appear as liquid but is provided lyophilized. Allow the product several minutes to solubilize after adding water. Mix thoroughly but gently Take extra care to mix thoroughly before each use, as the proteins tend to settle with the more dense layer after freezing.

Reference: AT1002-25ss

oYo-Link® Oligo Custom enables researchers to label their antibodies with custom oligonucleotides for iPCR, multiplexing, cell barcoding, Proximity Ligation Assays, CITE-Seq and more. Both ssDNA & dsDNA oligos are supported, up to 80bp or longer. Fill out the checkout form to specify your oligo sequence and phosphorothioate (PS) bond modifications. The Oligo cost is included in oYo-Link pricing. For Research Use Only. All Oligonucleotides are high-quality, manufactured by Integrated DNA Technologies, Inc. Catalog # AT1002. Requirements: To label your compatible antibodies with oYo-Link®, you will need a Light Source emitting at 365nm (6-10W). Use your own Compatible Device from the list here or purchase AlphaThera's LED Photo-Crosslinking Device Here. Oligo sequence is specified by customer at checkout. Technical Support: For Oligos with length > 80bp, fill out the Custom Oligo Checkout form. For additional questions concerning compatibility or oligo sequence specifications email support@alphathera.com

Reference: AS09 146S

Concentration: after adding 225 µl of milliQ water final concentration of the standard is 0.25 pmoles/ulProtein standard buffer composition: Glycerol 10%, Tris Base 141 mM, Tris HCl 106 mM, LDS 2%, EDTA 0.51 mM, SERVA® Blue G250 0.22 mM, Phenol Red 0.175 mM, pH 8.5, 0.1 mg/ml PefaBloc protease inhibitor (Roche), 50 mM DTT.This standard is ready-to-load and does not require any additions or heating. It needs to be fully thawed and thoroughly mixed prior to using. Avoid vigorous vortexing, as buffers contain detergent. Following mixing, briefly pulse in a microcentrifuge to collect material from cap.This standard is stabilized and ready and does not require heating before loading on the gel. Please note that this product contains 10% glycerol and might appear as liquid but is provided lyophilized. Allow the product several minutes to solubilize after adding water. Mix thoroughly but gently Take extra care to mix thoroughly before each use, as the proteins tend to settle with the more dense layer after freezing.

Reference: AT1002-25ds

oYo-Link® Oligo Custom enables researchers to label their antibodies with custom oligonucleotides for iPCR, multiplexing, cell barcoding, Proximity Ligation Assays, CITE-Seq and more. Both ssDNA & dsDNA oligos are supported, up to 80bp or longer. Fill out the checkout form to specify your oligo sequence and phosphorothioate (PS) bond modifications. The Oligo cost is included in oYo-Link pricing. For Research Use Only. All Oligonucleotides are high-quality, manufactured by Integrated DNA Technologies, Inc. Catalog # AT1002. Requirements: To label your compatible antibodies with oYo-Link®, you will need a Light Source emitting at 365nm (6-10W). Use your own Compatible Device from the list here or purchase AlphaThera's LED Photo-Crosslinking Device Here. Oligo sequence is specified by customer at checkout. Technical Support: For Oligos with length > 80bp, fill out the Custom Oligo Checkout form. For additional questions concerning compatibility or oligo sequence specifications email support@alphathera.com